2 Wire Control Signal SPD 5Vdc 10kV PLC Sensor Industrial Analog Loop Protection

Brand Name : LLH

Model Number : LS-CH5

Place of Origin : Guangdong Province.China

MOQ : 1 piece

Payment Terms : L/C,D/A,D/P,T/T,Western Union

Supply Ability : 5000-10000 pieces/mouth

Delivery Time : 7-15 days

Packaging Details : box

Price : US $10/ Piece

Nominal Operating Voltage (Un) : 5Vdc / 12Vdc / 24Vdc / 48Vdc

Maximum Continuous Operating Voltage (Uc) : 6Vdc / 18Vdc / 32Vdc / 60Vdc

Shock Rating (X-X,X-C C2) : 10kV/5kA

Shock Rating (X-X,X-C B2) : 4kV(10/700μs)

Shock Rating (X-X,X-C D1) : 2.5kA(10/350μs)

Voltage Protection Level (X-X @C2) : ≤15V / ≤30V / ≤60V / ≤95V

Response Time (tA) : ≤1ns

Load Current (IR) : 500mA

Contact Now

LS-CH Series 2-Wire Control Signal Lightning Arrester is designed for communication equipment such as dedicated communication lines, telemetry signals, measurement and control signals, PLC analog control systems, and 4-20mA current loops. Suitable for installation in LPZ 2-3 and subsequent lightning protection zones, it provides full-mode fine protection for two signal lines.

Featuring a plug-in module design, the product allows for easy replacement without interrupting signal transmission. The multi-level protection circuit ensures high flow rate and low residual voltage, effectively shielding signal lines from lightning-induced surges and electrostatic discharge. With a line-to-line bandwidth of 3MHz, it supports high-speed signal transmission without distortion.

Product Features
● It can simultaneously protect four communication signal lines.
● Multi level protection, high flow rate, and low residual pressure.
● The module can be hot swapped and replaced without interrupting signal transmission.
● Suitable for installation in LPZ 2-3 and subsequent lightning protection zones, it is a lightning arrester for communicationequipment such as communication dedicated lines, telemetry signals, measurement and control signals, PLC analogcontrol systems, and 4-20mA current loops.


Product Specification


2 Wire Control Signal SPD 5Vdc 10kV PLC Sensor Industrial Analog Loop Protection

Standards
IEC 61643.21
Models
LS-CH5/4
LS-CH12/4
LS-CH24/4
LS-CH48/4
Parameter
Nominal operating voltage Un
5Vdc
12Vdc
24Vdc
48Vdc
Maximum continuous operating voltage Uc
6Vdc
18Vdc
32Vdc
60Vdc
X-X,X-C Shock rating C2
10kV/5kA
X-X,X-C Shock rating B2
4kV(10/700μs)
X-X Up@C2
≤15V
≤30V
≤60V
≤95V
X-C Up@C2
≤500V
X-X Up@B2
≤10V
≤25V
≤45V
≤60V
X-C Up@B2
≤300V
Response time tA
≤1ns
Load current IR
500mA
Line to line bandwidth fG
3MHz
Protective Line
X1-X2,X3-X4,X1,X3-C,X2,X4-C

Mechanical parameters
Installation method
DIN Rail 35mm
Screw torque
1N*m
Strip length
10mm
Wiring cross-sectional area
0.5mm²-2.5mm²
Product size
90mmx75mmx12mm
Shell material and flame retardant grade
PC+ABS,UL 94 V-0
Installation location
Indoor
Shell protection rating
IP20
Temperature range
-40℃…+80℃
Humidity range
Relative humidity≤95%

Notices

1. Select the model based on the signal line's nominal operating voltage (5Vdc/12Vdc/24Vdc/48Vdc).

2. Use wiring with cross-sectional area 0.5mm²-2.5mm² and tighten screws to 1N·m torque.

3. The plug-in module design allows for easy replacement, but disconnect the signal line if possible during replacement.

4. Ensure reliable grounding with ground resistance 4Ω to guarantee surge diversion.

5. Avoid installing in environments with strong electromagnetic interference to prevent signal distortion.

6. Regularly inspect the module for loose connections or physical damage; replace if faulty.

FAQ

Q1: What is the difference between full-mode protection and line-line mode protection?

A1: Full-mode protection covers line-line and line-ground paths, while line-line mode only protects line-line paths. This product offers full-mode fine protection.

Q2: Can it be used for both DC and AC signal lines?

A2: It is specifically designed for DC signal lines (5Vdc/12Vdc/24Vdc/48Vdc). For AC signals, choose dedicated AC signal SPD models.

Q3: What is the load current capacity of the product?

A3: The maximum load current is 500mA, suitable for most industrial control signal lines.

Q4: Does the product require external power supply?

A4: No, it is passive and does not require external power supply, drawing minimal power from the signal line.

Q5: What is the service life of the product?

A5: Under normal operating conditions, the service life is 5-8 years. It may vary based on surge frequency and environmental factors.


Product Tags:

Signal Surge Protective Device 5Vdc

      

2 Wire Control Signal SPD

      

Analog Loop Protection Signal SPD

      
Quality 2 Wire Control Signal SPD 5Vdc 10kV PLC Sensor Industrial Analog Loop Protection for sale

2 Wire Control Signal SPD 5Vdc 10kV PLC Sensor Industrial Analog Loop Protection Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen LLH Electrical Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)